Description
This Display is intended for use with the Pressure Transducers illustrated in this catalogue where two volt free alarm
contacts are required. They can also be used in other applications where digital indication of an input value is
required. The displays are CE Marked in accordance with European Legislation.
14.2mm High LED’s
1/8 din case
Factory set user configured
2 SPCO volt free relay contacts
2 software alarms
90-265V ac or 12-24V dc input option
Front panel conforms to IP64
Square root extraction built in
Powers all Bailey & Mackey Transducers directly
General Specifications
Calibration
Accessed from front panel
Alarms
Two Software Alarms
Power Supply
Input 90 to 265V ac or 12 to 24V dc
On mains units it is recommended that a 50 mA anti-surge
fuse is fitted in the live input supply to the display
Part Number Suffixes
A 4-20 mA output
B 0-10V dc output
Ordering Information – Example
Type 442A
Supply 240V 50Hz
Calibration 0-10 bar