Description
The Statox 506 for the detection of toxic gases and oxygen
fully complies with SIL2
Like the Statox 505, the new Statox 506 is equipped with intelligent sensors from our own production.
They can detect NH3, HCN, Cl2, CO, O2, H2S, O3, NO2, H2, HCl, N2H4, COCl2,and SO2 with high sensitivity.
The sensor signal runs into the state-of-the-art electronics, which features safety functions such as “Heart – Beat” sensor monitoring, “Smart Sensor” technology and solid hardware and software monitoring.
Pure safety: SIL2 standard
The DIN EN 61508 standard makes functional safety measurable. This means that every sensor, every mechanical and electronic component, no matter how small, every software routine is monitored for its probability of failure.
The total of these paramters describes the probability of a failure while a dangerous gas is present. The probability of failure of the Statox 506, is far below the requirements of the standard – it even exceeds the requirements of the product standard for gas warning systems DIN EN 50420.
Easy to use: Plug & Play
The measuring head itself is gas-neutral. All technical parameters are stored in the F-RAM of the smart sensor. As soon as the sensor is plugged in, it communicates all important metrological data to the measuring head (gas type, measuring range, calibration data, manufacturing date, total exposure, etc.) and a short time later it is ready to measure. With this new generation of sensors, you can even query when a calibration or proof test is necessary.
Replacing the sensor is easy: Snap the sensor into the holder of the measuring head – and done.
This way, sensors located in hard to access areas can be conveniently calibrated in your workshop and then be quickly and easily reunited with the measuring head on site.
Technical Data – Transmitter Parameters | |||||||
Measure head: | Statox 506 (Type 5376) | ||||||
Measuring principle: | electrochemical | ||||||
Operation temperature: | -30 to +60°C | ||||||
Humidity: | 0 – 99 % r. H., non condensing | ||||||
Pressure: | 900 – 1100 hPa | ||||||
Accuracy at calibration concentration: | ± 10 % | ||||||
Power supply: | 28 VDC (12 – 28 VDC) | ||||||
Connections: | 2- or 3-Wire | ||||||
Terminal with: | 0,25 – 2,5 mm2 (AWG 24 – 12) | ||||||
Output: | 0 – 22 mA, max. Load 545 Ohm | ||||||
Display: | 8 – digits, 14 segments | ||||||
Dimensions (HxWxD): | 180 x 111 x 81 mm | ||||||
Weight: | 1200 g | ||||||
Housing material: | Cast aluminium, enameled / stainless steel | ||||||
Ingress protection EN 60529: | IP66 | ||||||
EMV: | EN 50270 | ||||||
ATEX marking: | Ex ib IIB T4 Gb | ||||||
Application: | II 2G | ||||||
Approval: | BVS 18 ATEX 066 X / N1 | ||||||
Power supply Ui : | max. 28 VDC | ||||||
Current Ii : | max. 93 mA | ||||||
Leitung Pi : | 650 mW | ||||||
Internal capacity Ci : | 24 nF | ||||||
Internal inductivity Li : | neglectable | ||||||
Functional safety: | SIL2 compliant with IEC 61508 |
Buyer Notice
1. About the product
Due to market fluctuations, exchange rate changes, and other factors, product prices and product attributes are for reference only; The specific product requirements are subject to customer requirements, and the price is based on the communicated quotation. All product prices on this website are not considered transaction prices and are for reference only!
2. About Trademark Copyright
All company names, trademarks, logos, product images, product descriptions, product brand names, and trademark copyrights related to this website belong to the corresponding brands; This website is only designed for the convenience of product identification.
Please carefully read the buyer’s instructions to avoid unnecessary disputes.
Reviews
There are no reviews yet.