COMPUR Monitors Stationary Gas detectors Statox 506 SIL2

Brand:COMPUR Monitors
Model:Statox 506
If you want to learn about the product, please contact us.
Please provide the brand, model, and quantity for inquiry.

Category:

Description

The Statox 506 for the detection of toxic gases and oxygen

fully complies with SIL2

Like the Statox 505, the new Statox 506 is equipped with intelligent sensors from our own production.

They can detect NH3, HCN, Cl2, CO, O2, H2S, O3, NO2, H2, HCl, N2H4, COCl2,and SO2 with high sensitivity.

The sensor signal runs into the state-of-the-art electronics, which features safety functions such as “Heart – Beat” sensor monitoring, “Smart Sensor” technology and solid hardware and software monitoring.

Pure safety: SIL2 standard

The DIN EN 61508 standard makes functional safety measurable. This means that every sensor, every mechanical and electronic component, no matter how small, every software routine is monitored for its probability of failure.

The total of these paramters describes the probability of a failure while a dangerous gas is present. The probability of failure of the Statox 506, is far below the requirements of the standard – it even exceeds the requirements of the product standard for gas warning systems DIN EN 50420.

Easy to use: Plug & Play

The measuring head itself is gas-neutral. All technical parameters are stored in the F-RAM of the smart sensor. As soon as the sensor is plugged in, it communicates all important metrological data to the measuring head (gas type, measuring range, calibration data, manufacturing date, total exposure, etc.) and a short time later it is ready to measure. With this new generation of sensors, you can even query when a calibration or proof test is necessary.

Replacing the sensor is easy: Snap the sensor into the holder of the measuring head – and done.

This way, sensors located in hard to access areas can be conveniently calibrated in your workshop and then be quickly and easily reunited with the measuring head on site.

Technical Data – Transmitter Parameters
Measure head: Statox 506 (Type 5376)
Measuring principle: electrochemical
Operation temperature: -30 to +60°C
Humidity: 0 – 99 % r. H., non condensing
Pressure: 900 – 1100 hPa
Accuracy at calibration concentration: ± 10 %
Power supply: 28 VDC (12 – 28 VDC)
Connections: 2- or 3-Wire
Terminal with: 0,25 – 2,5 mm2 (AWG 24 – 12)
Output: 0 – 22 mA, max. Load 545 Ohm
Display: 8 – digits, 14 segments
Dimensions (HxWxD): 180 x 111 x 81 mm
Weight: 1200 g
Housing material: Cast aluminium, enameled / stainless steel
Ingress protection EN 60529: IP66
EMV: EN 50270
ATEX marking: Ex ib IIB T4 Gb
Application: II 2G
Approval: BVS 18 ATEX 066 X / N1
Power supply Ui : max. 28 VDC
Current Ii : max. 93 mA
Leitung Pi : 650 mW
Internal capacity Ci : 24 nF
Internal inductivity Li : neglectable
Functional safety: SIL2 compliant with IEC 61508

 

 

 

Buyer Notice
1. About the product
Due to market fluctuations, exchange rate changes, and other factors, product prices and product attributes are for reference only; The specific product requirements are subject to customer requirements, and the price is based on the communicated quotation. All product prices on this website are not considered transaction prices and are for reference only!
2. About Trademark Copyright
All company names, trademarks, logos, product images, product descriptions, product brand names, and trademark copyrights related to this website belong to the corresponding brands; This website is only designed for the convenience of product identification.
Please carefully read the buyer’s instructions to avoid unnecessary disputes.

Reviews

There are no reviews yet.

Be the first to review “COMPUR Monitors Stationary Gas detectors Statox 506 SIL2”