Premium bench-top ventilator tester for engineers and health care professionals.

Test, verify and calibrate any kind of medical device that generates pressure or produces flow such as ventilators, respirators and anaesthesia machines.

The FlowAnalyser measures bi-direction flow, various pressures, temperature, humidity and O2 concentrations. The unique measuring modes for adult, pediatric and high frequency ventilators decreases test duration significantly. It incorporates remote control interface, data storage, internal battery and the high-end PC-based Software tool FlowLab.

Technical Specifications

Measuring your pneumatic equipment for reliability and precision with a dependable calibration tool is critical in avoiding fatal errors. Precision and reliability are exactly what the FlowAnalyser Product Line provides.

The FlowAnalyser ventilator tester measures flow, pressure, temperature, humidity and O₂ concentrations bidirectionally. The one-of-a-kind Adult, Pediatric and High Frequency ventilation measuring modes make the FlowAnalyser the ideal calibration tool for all ventilators, anesthesia machines and spirometers.

Our biomedical testing devices PF-300, PF-301 or PF-302 distinguish themselves from other calibration tools by combining a simple, intuitive multilingual user interface with the highest precision. All measured values can be stored directly on the FlowAnalyser and later retrieved for documentation purposes with the push of a button. FlowLab software complements the FlowAnalyser Ventilator tester by offering a wide range of graphical analysis capabilities. Swiss devotion to detail at its best!

Flow and pressure measurement PF-300 PF-301 PF-302
Flow
Flow in High-Flow-Channel FlowHigh ±300 L/min***
±1.75 %* or ±0.1 L/min**
Flow in Low-Flow-Channel FlowLow ±20 L/min***
±1.75 %* or ±0.04 L/min**
Measuring bidirectional   yes
Temperature compensated   automatic
Pressure compensated   automatic
Humidity compensated   automatic
Oxygen compensated automatic
Pressure
High PHigh 0–10 bar
±1 %* or ±10 mbar**
Differential PDiff ±150 mbar
±0.75 %* or ±0.1 mbar**
   
Relative Pressure   ±150 mbar
±0.75 %* or ±0.1 mbar**
 
Flow channel PChannel 0–150 mbar
±0.75 %* or ±0.1 mbar**
Atmospheric pressure PAtmo 0–1150 mbar (abs)

±1 %* or ± 5 mbar**

Low PLow 0–5 mbar

±1 %* or ± 0.01 mbar**

Vacuum PVac ± 1000 mbar

±0.5 %* or ± 2 mbar**

Units
Flow   L/min, L/s, cfm, mL/min, mL/s
Pressure   bar, mbar, cmH2O, inH2O, Torr, inHg, hPa, kPa, mmHg, PSI
Other measurement
Oxygen
(pressure comp. ≤ 150 mbar)
O2 0–100 %
±1 % O2**
Gas temperature Temp. 0–50°C
±1.75 %* or ±0.5 °C**
Gas humidity Humidity 0–100% RH (non condensing)
±3 % RH ** from 10% RH to 80% RH
±5 % RH ** for < 10% and > 80% RH
Gas types   Air, Air/O2, O2, N2O, N2O/O2, N2, He , He/O2, customised gas types
Further gas types
CO2 concentration (with optional OR-703) 0–10 %, ±(0.2 % ABS + 2 % REL)

10–20 %, ±(0.3 % ABS + 4 % REL)

Optional Optional Optional
N2O concentration (with optional OR-703) 0–100 %, ±(2 % ABS + 2 % REL) Optional Optional Optional
HAL, ISO, ENF concentration (with optional OR-703) 0–8 %, ±(0.15 % ABS + 5 % REL)

8–12 %, ±(0.2 % ABS + 10 % REL)

Optional Optional Optional
SEV concentration (with optional OR-703) 0–10 %, ±(0.15 % ABS + 5 % REL)

10–15 %, ±(0.2 % ABS + 10 % REL)

Optional Optional Optional
DES concentration (with optional OR-703) 0–22 %, ±(0.15 % ABS + 5 % REL)

22–25 %, ±(0.2 % ABS + 10 % REL)

Optional Optional Optional
Gas standards   ATP, ATPD, ATPS, AP21, STP, STPH, BTPS, BTPS-A, BTPD, BTPD-A, 0/1013, 20/981, 15/1013, 25/991, 20/1013, NTPD, NTPS
Ventilation Parameter
Breath rate Rate 1–1000 bpm
±1 bpm* or ±2.5 %**
Time Ti, Te 0.05–60s
±0.02 s
Ratio I:E 1:300–300:1
±2.5 %*
  Ti/Tcyc 0–100 %
±5 %*
Volume V(Low), V(High) ±1.75 %* or ±0.10 mL (>2.4 L/min)**
±1.75 %* or ±0.20 mL (>6.0 L/min)**
Tidal volume Vti, Vte ± 10 L

±1.75 %* or ±0.10 mL (>2.4 L/min)**
±1.75 %* or ±0.20 mL (>6.0 L/min)**

Minute volume Vi, Ve 0–300 L/min
±2.5 %*
Peak flow PFInsp, PFExp ± 300 L/min
±1.75 %* or ±0.1 L/min**
Pressure PPeak, PMean, PEEP, PPlateau 0–150 mbar
±0.75 %* or ±0.1 mbar**
Compliance CStat 0–1000 mL/mbar
±3 %* or ±1 mL/mbar**
General information
Display   Intuitive user interface with numerical measuring values, statistics, volume trigger configuration, gas type selection and calibration menus.
Interfaces   USB for Windows Software FlowLab, RS-232 for individual communication, TTL for external trigger and TSI4000 Protocol.
Data Storage   Internal
Power   100–240 VAC, 50/60 Hz
Power consumption 25 VA
Dimension (w × d × H)   22 × 25 × 12 cm
Weight   3.7 kg
Battery   3 hours (with OR-703 2 hours)
Emlators RT-200, TSI4000
Approvals   CE, CSA (North America), IEC 61010-1:2010, IEC 61326-2:2012
The greater tolerance is valid:
* Tolerance related to the measured value,
** Absolute tolerance,
*** The unit L/min is based on ambient conditions of 0 °C and 1013.25 mbar (DIN 1343).

 

 

 

 

Buyer Notice
1. About the product
Due to market fluctuations, exchange rate changes, and other factors, product prices and product attributes are for reference only; The specific product requirements are subject to customer requirements, and the price is based on the communicated quotation. All product prices on this website are not considered transaction prices and are for reference only!
2. About Trademark Copyright
All company names, trademarks, logos, product images, product descriptions, product brand names, and trademark copyrights related to this website belong to the corresponding brands; This website is only designed for the convenience of product identification.
Please carefully read the buyer’s instructions to avoid unnecessary disputes.

Reviews

There are no reviews yet.

Be the first to review “IMT Analytics FlowAnalyser PF-300”