Description
Premium bench-top ventilator tester for engineers and health care professionals with a beautiful, high resolution multi-touch user interface that is completely configurable.
The FlowAnalyser PRO with its extreme precision and reliability, is capable of testing a wide range of medical devices such as respiratory and anesthesia devices, oxygen flow meters, pressure gauges and suction devices.
It incorporates unique automatic breath detection, a remote-control interface, data storage, internal battery, and FlowLab, the high-end PC-based Software tool.
Biomedical Test-Sets
FlowAnalyser PF-300 PRO test sets combine PF-300 PRO with comprehensive accessories suitable for calibration and verification of all ventilators and anesthesia machines.
- Automatic Breath Detection
- Highest Flow Accuracy
- Ultra-Low Flow Measurement
- Pressure & Vacuum Measurements
- High Resolution Multi-touch Display
- Lightweight Portability
- 16-Hour Battery Life
- Integrated Apps with Guided Test Sequences
- SmartLung 2000
- FlowLab Software
- OR-703 MultiGasAnalyser
Highest Flow Accuracy
The FlowAnalyser PRO measures ultra-low flow, with a range of -1 to 1 L/min, to test low-flow anesthesia devices, sidestream capnometers, pneumatic valves, rinse flows, oxygen flow meters and more.
The main flow channel measures all respiratory parameters for infant, pediatric, adult, and high frequency ventilators including oxygen concentration, gas temperature and humidity.
Apps with Test Sequences
Run tests easier and faster with our apps.
The FlowAnalyser PRO ventilator tester supports apps for testing and calibrating many devices. The apps enable fast and accurate testing. Entire test sequences are displayed with images and texts and measurements are taken automatically. The test results are recorded in a PDF report, that can be signed directly on the screen.
Automatic Breath Detection
Measure breath based respiratory parameters with automatic trigger detection for conventional and high-frequency medical ventilators.
The FlowAnalyser PRO can automatically detect the breath phase, inhalation or exhalation, for a wide range of respiratory devices, including BiPAP machines, and high frequency ventilators. For high-frequency ventilators, breaths up to 2000 bpm can be precisely measured.
Easy to Use Interface
The FlowAnalyser PRO offers a beautiful, high resolution multi-touch user interface that is completely configurable.
The Direct-Access keys allow you to see at a glance which parameters are measured by each port.
Selecting any Direct-Access key displays the parameter and its limits to make using the FlowAnalyser PRO intuitive and easy.
Flow and pressure measurement | |||||
Flow | |||||
Flow-Channel | Flow | ±300 L/min*** ±1.65 %* or ±0.04 L/min (for 10..40 °C)** |
|||
Ultra-Low-Flow-Channel | FlowUltra-Low | ±1 L/min*** ±1.65 %* or ±0.01 L/min (for 10..40 °C)** |
|||
Measuring bidirectional | yes | ||||
Temperature compensated | automatic | ||||
Pressure compensated | automatic | ||||
Humidity compensated | automatic | ||||
O2 compensated | automatic | ||||
Pressure | |||||
High Pressure & Vacuum | PHigh | -1–10 bar ±1 %* or ±7 mbar** |
|||
Differential Pressure | PDiff | ±250 mbar ±0.5 %* or ±0.1 mbar** |
|||
Low Differential Pressure | PDiff Low | -10–10 mbar ±1 %* or ±0.01 mbar** |
|||
Pressure in Flow Channel | PChannel | -50–160 mbar ±0.5 %* or ±0.1 mbar** |
|||
Atmospheric pressure | PAtmo | 500–1240 mbar ±1 %* or ±5 mbar** |
|||
Units | |||||
Flow | L/min, L/s, cfm, mL/min, mL/s | ||||
Pressure | bar, mbar, cmH2O, inH2O, Torr, inHg, hPa, kPa, mmHg, PSI | ||||
Additional measurements | |||||
Oxygen | O2 | 0–100 % ±1 % O2** |
|||
Temperature | In Flow Channel | 0–50°C ±1.75 %* or ±0.5 °C** |
|||
Dew point | In Flow Channel | -10–50°C ±2 %* or ±1 °C** |
|||
Humidity | In Flow Channel | 0–100% RH (non condensing) ±3 % RH ** from 10% RH to 80% RH ±5 % RH ** for < 10% and > 80% RH |
|||
Gas types | Air, Air/O2, O2, N2O, N2O/O2, N2, He , He/O2 , CO2, customised gas types | ||||
Further gas types | |||||
CO2 | concentration (with optional OR-703) | 0–15 vol%, ±(0.2 vol% + 2 % of reading)
15–25 vol%, unspecified |
|||
N2O | concentration (with optional OR-703) | 0–100 vol%, ±(2 % vol% + 2 % of reading) | |||
HAL, ISO, ENF | concentration (with optional OR-703) | 0–8 vol%, ±(0.15 vol% + 5 % of reading)
8–25 vol%, unspecified |
|||
SEV | concentration (with optional OR-703) | 0–10 vol%, ±(0.15 vol% + 5 % of reading)
10–25 vol%, unspecified |
|||
DES | concentration (with optional OR-703) | 0–22 vol%, ±(0.15 vol% + 5 % of reading)
22–25 vol%, unspecified |
|||
Gas standards | ATP, ATPD, ATPS, AP21, AP25, STP, STPD0, STPD20, STPD21, STPH, BTPS, BTPS-A, BTPD, BTPD-A, 0/1013, 20/981, 15/1013, 25/991, 20/1013, 23/1013, NTPD, NTPS | ||||
Respiratory Parameter | |||||
Breath rate | Rate | 1–2000 bpm ±1 bpm* or ±1 %** |
|||
Inspiratory time | Ti | 0.01–60s ±0.01 s |
|||
Expiratory time | Te | 0.01–90s ±0.01 s |
|||
Inspiratory hold time | TiH | 0–60s ±0.01 s |
|||
Expiratory hold time | TeH | 0–90s ±0.01 s |
|||
Post-inspiratory pause | % Tp | 0–100 % ±0.1 % |
|||
Ratio | I:E | 1:300–300:1 ±2 %* |
|||
Ti/TTotal | 0–100 % ±5 %* |
||||
Breath Volume | Vti, Vte | ±60 L ±1.75 %* or ±0.10 mL |
|||
Minute Volume | Vi, Ve |
0–300 L/min |
|||
Pressure | PPeak, PMean, PEEP, PPlateau | 0–160 mbar ±0.75 %* or ±0.1 mbar** |
|||
Peak flow | PFInsp, PFExp | ± 300 L/min ±1.65 %* or ±0.04 L/min** |
|||
Compliance | CStat | 0–1000 mL/mbar ±3 %* or ±0.01 mL/mbar** |
|||
Trigger | Automatic, Adult, Pediatric, HFO, ext. Trigger | Adult, Pediatric, HFO; Adjustable on flow or pressure curves with user-defined limits. | |||
General information | |||||
Power | 100–240 VAC, 50/60 Hz | ||||
Battery operation | 16 hours | ||||
Power consumption | Typical 5 VA, max. 25 VA (during battery charging) | ||||
Weight | 3.2 kg | ||||
Dimension (w × d × H) | 24 × 26 × 13 cm | ||||
Data Storage | Internal, USB stick | ||||
Display | High resolution touch-screen display 5″ (800 × 480 px) | ||||
Interfaces | USB-A for USB stick, USB-B for FLowLab Software, individual communication, TTL for external trigger, RS232 | ||||
Calibration | Annually | ||||
Operating temperature | 10–40 °C (50–104 °F) | ||||
Operating humidity | 10–90 % R.H.*** | ||||
Approvals | CE, CSA (North America), IEC 61010-1:2010/AMD1:2016, IEC 61326-1:2020 | ||||
The greater tolerance is valid: * Tolerance related to the measured value, ** Absolute tolerance, with steady air flow, *** Non-condensing, **** The unit L/min is based on ambient conditions of 0 °C and 1013.25 mbar (DIN 1343). |
Buyer Notice
1. About the product
Due to market fluctuations, exchange rate changes, and other factors, product prices and product attributes are for reference only; The specific product requirements are subject to customer requirements, and the price is based on the communicated quotation. All product prices on this website are not considered transaction prices and are for reference only!
2. About Trademark Copyright
All company names, trademarks, logos, product images, product descriptions, product brand names, and trademark copyrights related to this website belong to the corresponding brands; This website is only designed for the convenience of product identification.
Please carefully read the buyer’s instructions to avoid unnecessary disputes.
Reviews
There are no reviews yet.