Description
If you value your flow, find value in the data from a Max Gear Meter. From heavy duty hydraulics to adhesive dispensing, Max Gear Meters provide more data per liter of fluid to give you more control of your flow.
Choose from frequency or analog transmitter options. High tempe
Description
Flow | 25 cc/min to 45 liters/min; 0.006 to 11.88 gpm |
Port Size | 1/2″ NPT or #8 SAE or Manifold Mount |
Accuracy | (at 30 cP): ± 0.3% of reading over a 100:1 range |
Pressure | 6000 psi (414 bar) maximum |
K-Factor | 70,000 pulses/L |
Fluids | Most non aqueous, hydrocarbon based liquids |
Specifications
MECHANICAL
Filtration
|
30 Micron recommended
|
Weight
|
3.7 kg (8.1 lbs)
|
MATERIALS OF CONSTRUCTION
External
|
Stainless steel, type 303; Fluoropolymer coated bolts;
MoS2 lubricant
|
Wetted
|
Stainless steel, type 303, 440C, 17-4;
Nickel plated SmCo magnet
|
O-Rings
|
Standard: Viton®
Optional: Teflon®, Perfluoroelastomer |
TRANSMITTER VARIATIONS
Signal Type
|
Output
|
Resolution (K-Factor)
|
Std. Temp†
|
High Temp†
|
Ultra Temp
|
---|---|---|---|---|---|
Frequency
|
5 VDC square wave (current sinking available)
|
70,000 pulses/L
|
90°C
|
155°C
|
225°C
|
Frequency
|
5 VDC quadrature (2-phase)
|
35,000 pulses/L/phase
|
90°C
|
155°C
|
225°C
|
Analog
|
0-10 VDC
|
Uni or Bi-directional
|
90°C
|
155°C
|
225°C
|
Analog
|
4-20 mA
|
Uni or Bi-directional
|
90°C
|
155°C
|
225°C
|
Compliance:
|
CE Certified, Ex-proof version available with ATEX/IECEx II 2 G Ex db IIB Tx Gb as well as UL, cUL certification for Class 1, Division 1, Groups C and D, Tx.†Maximum temperature rating for ATEX certified transmitters is 75°C Std. Temp and 130°C High Temp.
|
Applications
-
Hydraulic Valve, Pump, and Cylinder Testing
Testing of hydraulic valves, pumps and cylinders covers a wide range of flows. From full flow…
-
Chemical Additives Injection Measurement
Chemical additives injection is a broad description for a varied set of applications that require a…
-
Hot Melt Adhesive Dispensing Applications Measured to a Fraction of a Gram
Quality and performance can change with a small amount of material in thermoplastic and reactive hotmelt…
-
Precise Polyurethane Ratio Control
Polyol and isocyanate blending applications for cast elastomers, and rigid or flexible foam applications such as…
-
Aviation Hydraulic Testing
Testing of hydraulic fluid throughout an aircraft’s hydraulic pumps, motors, cylinders and actuators to operate wheel…
Buyer Notice
1. About the product
Due to market fluctuations, exchange rate changes, and other factors, product prices and product attributes are for reference only; The specific product requirements are subject to customer requirements, and the price is based on the communicated quotation. All product prices on this website are not considered transaction prices and are for reference only!
2. About Trademark Copyright
All company names, trademarks, logos, product images, product descriptions, product brand names, and trademark copyrights related to this website belong to the corresponding brands; This website is only designed for the convenience of product identification.
Please carefully read the buyer’s instructions to avoid unnecessary disputes.
Reviews
There are no reviews yet.