Description
Measure high viscosity fluids up to 1,000,000 cPs or higher volumes of hydraulic fluids and fuels to get higher resolution data with a lower pressure drop than typical application meters.
Choose from frequency or analog transmitter options. High temperature models up to 225°C available. CE Certified, Ex-proof version available with ATEX/IECEx and UL/cUL certifications.
Flow | 100 cc/min to 189 liters/min; 0 to 50 gpm |
Port Size | 1.5″ NPT or 1.5″ (DN40) flange |
Accuracy | (at 30cp): ± 0.2% of reading over 50:1 range |
Pressure | 500 or 3500 psi (35 or 240 bar) |
K-Factor | 15,000 pulses/L |
Fluids | Most non aqueous, hydrocarbon based liquids |
Specifications
MECHANICAL
Filtration
|
150 Micron recommended
|
Weight
|
13.6 kg (30.0 lbs)
|
MATERIALS OF CONSTRUCTION
External
|
Stainless Steel, type 303
|
Wetted
|
Stainless Steel, type 303, 440C
|
O-Rings
|
Standard: Viton®
Optional: Teflon®, Perfluoroelastomer |
TRANSMITTER VARIATIONS
Signal Type
|
Output
|
Resolution (K-Factor)
|
Std. Temp†
|
High Temp†
|
Ultra Temp
|
---|---|---|---|---|---|
Frequency
|
5 VDC square wave (current sinking available)
|
15,000 pulses/L
|
90°C
|
EX†
|
225°C
|
Frequency
|
5 VDC quadrature (2-phase)
|
7500 pulses/L/phase
|
90°C
|
EX†
|
225°C
|
Analog
|
0-10 VDC
|
Uni or Bi-directional
|
90°C
|
EX†
|
225°C
|
Analog
|
4-20 mA
|
Uni or Bi-directional
|
90°C
|
EX†
|
225°C
|
Compliance:
|
CE Certified, Ex-proof version available with ATEX/IECEx II 2 G Ex db IIB Tx Gb as well as UL, cUL certification for Class 1, Division 1, Groups C and D, Tx.†Maximum temperature rating for ATEX certified transmitters is 75°C Std. Temp and 130°C High Temp.
|
Applications
-
Gasoline and Diesel Fuel Measurement
Gasoline and diesel fuel measurement from single injector testing to on-vehicle flow measurement across the automotive…
-
Hydraulic Valve, Pump, and Cylinder Testing
Testing of hydraulic valves, pumps and cylinders covers a wide range of flows. From full flow…
-
Precise Defoamer Ratio Control
Aqueous and Non-aqueous antifoaming and defoaming solutions and dispersants are used in a variety of processes…
Buyer Notice
1. About the product
Due to market fluctuations, exchange rate changes, and other factors, product prices and product attributes are for reference only; The specific product requirements are subject to customer requirements, and the price is based on the communicated quotation. All product prices on this website are not considered transaction prices and are for reference only!
2. About Trademark Copyright
All company names, trademarks, logos, product images, product descriptions, product brand names, and trademark copyrights related to this website belong to the corresponding brands; This website is only designed for the convenience of product identification.
Please carefully read the buyer’s instructions to avoid unnecessary disputes.
Reviews
There are no reviews yet.