It can:
• Catch power quality events such as fast transients (impulses) to 8 microseconds, voltage sags (dips), and swells.
• Measure total and individual harmonic distortion to the 50th harmonic
• Record energy use (kWh), and log all power parameters: watts, VA, Power Factor, etc.
• Data log RMS voltage and current over time (days/weeks/months) with down to one second resolution
• Display real time values in meter window – just like a multimeter
• Display oscilloscope waveforms, harmonic spectra, phasors via a PC and Bluetooth wireless communications
• Measure DC voltage and current
• Monitor 50Hz, 60Hz, 400Hz, and variable frequency systems

HANDS-ON CHOICE!
It’s rubberized contoured case and rugged construction make the PS4500 ideal for field work. Clearly labeled buttons display present maximum, minimum, and average values on a back-lit LCD screen for quickly making spot measurements and over-all evaluation at panels and equipment. Our patented SureStart feature automatically checks for wrong connections before you begin monitoring to ensure a successful power study every time.
Use it on just about any type of power system in the world. Redundant communications and data storage so there is always a way to communicate and get data. Set logging period from 1 second to 99 minutes for months of logging. At 1 second logging, capacity is limited by the size of your SD card (32GB maximum). Data is saved to internal memory that can be downloaded to a PC via Bluetooth. Alternatively, the PS4500 includes a removable SD memory card slot that allows you to backup power survey data and transfer the data to a PC via an SD card. PC software and Report Writer are included.
EVERY CYCLE EXAMINED – FAST!
High-speed sampling to 8 microseconds offers high performance for capturing spikes and transients. Cycle-by-cycle RMS measurement provides the greatest accuracy for data logging. Half-cycle RMS measurement provides highest resolution for triggering and tracking voltage fluctuations. Continuous sampling ensures no cycle is missed on any input. The meter is never “blind” or idling.
SAFE FOR NFPA 70E AND CSA Z462 COMPLIANCE
The new safety regulations demand safer tools. The PowerSight PS4500 has a 600V CAT IV safety rating – the smart choice for working on systems to 600V.
Be Comfortable. Be Safe. Get relief from wearing PPE.
PowerSight meters and analyzers with Bluetooth wireless communications are the safest way to test. After installing the PowerSight analyzer and its probes, you can get safely away from high voltages and Arc Flash dangers and test remotely. At a safe distance, cumbersome PPE suits, hoods, gloves, etc. can be removed. Thus workers can more comfortably control their PowerSight analyzer, view connections, phasors, and real-time values, start/stop monitoring and download data in complete safety (up to 25 feet away) via their laptop or tablet computer.
Features
Measures, logs, and reports:

RMS Volts
RMS Amps
Sags, Swells (surges) and inrush
Transients, impulses
Watts, VA , VAR , Power Factor, Hz
THD, Live / scope waveform views
Real time meters
Phasors
Harmonic Spectrum
Specifications
General Specs
Category Notes
Size 3.89″ (9.86 cm) W x 7.72″ (19.61 cm) L x 1.58″ (4.01 cm) Deep at bottom end; 2.14″ (5.44 cm) Deep at top end
Weight 1.1 lbs (0.5 kg)
Operating Range 32 – 122 degrees F (0 – 50 degrees C) Relative humidity to 70% (non-condensing)
Power Requirement 12V DC @ 500 mA
Battery Life 8-10 hours after 4 hour charge
Battery Type Li-ion
Sampling Rate 8 microseconds for Voltage and Current
Safety 600V CAT IV
SD Card Slot Accepts SD Cards to 32GB
Logging Period (Resolution) 1 Second – 99 Minutes
Logging Duration (Length of session) up to 2 years according to memory allocation
Voltage Measurement
Category Notes
Range 1-1000 Vrms Steady-State (direct input)
Display Range 1-6000 kV (using input ratios)
Accuracy ±0.1 % of reading ±0.3 Vrms
Current Measurement
Category Notes
Range Depends on probes
Display Range 1 mA – 6 Megamps (using input ratios)
Accuracy ±0.1 % of reading plus accuracy of probes
Frequency Measurement
Category Notes
Range DC, 22 – 200 Hz, 360 – 440 Hz Fundamental
Accuracy ±0.25%
Harmonics Measurement
Category Notes
Range 22 – 3000 Hz (50th Harmonic @ 50/60 Hz)
Accuracy ±0.25%
Triggering
Category Notes
Swell/Sag (Dip)/Inrush 1/2 Cycle RMS
Transient Detection 8 microseconds, instantaneous
Harmonics Accuracy ±0.25%

Buyer Notice

1. About the product

Due to market fluctuations, exchange rate changes, and other factors, product prices and product attributes are for reference only; The specific product requirements are subject to customer requirements, and the price is based on the communicated quotation. All product prices on this website are not considered transaction prices and are for reference only!

2. About Trademark Copyright

All company names, trademarks, logos, product images, product descriptions, product brand names, and trademark copyrights related to this website belong to the corresponding brands; This website is only designed for the convenience of product identification.

Please carefully read the buyer’s instructions to avoid unnecessary disputes.

Reviews

There are no reviews yet.

Be the first to review “PowerSight PS4500 Power Quality Analyzer”