Statox 560 – Self-Test with Real-Gas

Detection of phosgene COCl2, chlorine Cl2, hydrocyanic acid HCN, carbon monoxide CO, hydrochloric acid HCl, ammonia NH3 or hydrogen sulfide H2S (others on request) at the highest level of security!

Functional safety with SIL2 is a measure of the extremely low probability of failure if necessary. In addition, a self-test with real gas guarantees that a malfunction – no matter how unlikely – does not go unnoticed with this gas warning device.

The maintenance requirement can also be determined with the self-test. This saves a lot of time for inspection rounds.

The Statox 560 is a state-of-the-art product in every respect:

  • The new generation of sensors shines with high sensitivity, very fast response, low cross-sensitivities and plug-and-play technology.
  • The gas generators produce the gas to be measured during the self-test. This ensures that the sensor works perfectly in terms of measurement technology.
  • The output signals are a 4 – 20 mA analog signal plus 4 open collector outputs for A1, A2, maintenance request and system failure.
  • The entire electronics are housed in an Ex d housing with a window. The self-test takes place automatically once a day at a programmable time. However, it can also be triggered by hand with a magnetic pen. The self-test can also be started from your control room. This can be done with a separate button or with the Statox 503 control module.
  • With the supplied magnetic pen, parameters can be set and various information can be called up. Since the housing does not have to be opened, no fire permit is required.
  • The sensor module contains the sensor, the generator cell and a micropump. It is designed in protection class Ex i. No fire permit is required for work on this module. The module can be completely removed and replaced with a new one. This structure reduces the work required in the field to an absolute minimum.
Technical Data:
Product name: Statox 560 (Type 5377)
電源: 24 (16-30) VDC
消費電力: max. 2.7 W (8.7 W for COCl2) at input voltage ≤ 26 VDC
動作温度: -30~+60°C
プレッシャーだ: 700 to 1300 hPa
湿度: 0 to 99% r. H., non condensing
アプリケーション II 2G
Explosion protection: Ex d ib IIC T4 Gb (at Um = 30 VDC for all connections)
EC type examination certificate: BVS 16 ATEX E 065 X
Protection class EN60529: IP66 (gas intake IP54)
ディスプレイ 2 x 16 signs, illuminated
住宅だ: Cast aluminum epoxide varnish / stainless steel
コネクションだ: 10-core cable tail (1 m) or 7-pin eXLink plug
Open-Drain-outputs: 2 x alarm, 1 x system failure, 1 x maintenance request
Characteristic values max. 30 VDC / 2.5 A
SF-Open-Drain- output: In normal operation active (conductive)
Analog output: 0 mA in case of system failure
2 or 4 mA in the service mode, programmable
4 – 20 mA in the measuring mode
22 mA when full scale is exceeded
max. burdon: 450 Ohm
EMC: EN 61000-6-4:2007 + A1:2011 / EN 50270:2015 (type 2)
機能安全: SIL 2 compliant according to IEC 61508:2010
Automatic self-test: every 24 hours, time is selectable
体重だ: ca. 4800 g
寸法(WxHxD): 121 x 294 x 138 mm
Selftest
Gas Formula Test Gas
Chlorine Cl2 Cl2
Phosgene COCl2 COCl2
Hydrogen sulfide H2S H2S
Hydrogen cyanide HCN HCN
Ammonia NH3 H2S
Hydrogen chloride HCl H2S

 

 

 

 

バイヤー通知
1.製品について
市場の変動、為替レートの変化、その他の要因のため、製品価格と製品属性は参考のみであり、具体的な製品要件は顧客の要件に従うものとし、価格は連絡された見積書に基づくものとします。本ウェブサイト上の製品価格はすべて取引価格とはみなされず、参考価格となります!
2.商標権について
当ウェブサイトに掲載されている会社名、商標、ロゴ、商品画像、商品説明、商品ブランド名、商標の著作権は、各ブランドに帰属します。
不必要な紛争を避けるため、バイヤーの指示をよくお読みください。

レビュー

レビューはまだありません。

“COMPUR Monitors Leak Detection Gas Detector Statox 560” の口コミを投稿します