{"id":8963,"date":"2024-07-26T11:37:43","date_gmt":"2024-07-26T03:37:43","guid":{"rendered":"http:\/\/www.wbusi.com\/?post_type=product&#038;p=8963"},"modified":"2024-07-26T11:37:43","modified_gmt":"2024-07-26T03:37:43","slug":"imt-analytics-flowanalyser-pf-300","status":"publish","type":"product","link":"https:\/\/www.wbusi.com\/ja\/product\/imt-analytics-flowanalyser-pf-300\/","title":{"rendered":"IMT\u30a2\u30ca\u30ea\u30c6\u30a3\u30af\u30b9\u793e \u30d5\u30ed\u30fc\u30a2\u30ca\u30e9\u30a4\u30b6\u30fc PF-300"},"content":{"rendered":"<article class=\"product-description__text text-white\">\n<p class=\"lead\">Premium bench-top ventilator tester for engineers and health care professionals.<\/p>\n<p>Test, verify and calibrate any kind of medical device that generates pressure or produces flow such as ventilators, respirators and anaesthesia machines.<\/p>\n<p>The FlowAnalyser measures bi-direction flow, various pressures, temperature, humidity and O<sub>2<\/sub> concentrations. The unique measuring modes for adult, pediatric and high frequency ventilators decreases test duration significantly. It incorporates remote control interface, data storage, internal battery and the high-end PC-based Software tool FlowLab.<\/p>\n<h3>\u6280\u8853\u4ed5\u69d8<\/h3>\n<p>Measuring your pneumatic equipment for reliability and precision with a dependable calibration tool is critical in avoiding fatal errors. Precision and reliability are exactly what the FlowAnalyser Product Line provides.<\/p>\n<p>The FlowAnalyser ventilator tester measures flow, pressure, temperature, humidity and O\u2082 concentrations bidirectionally. The one-of-a-kind Adult, Pediatric and High Frequency ventilation measuring modes make the FlowAnalyser the ideal calibration tool for all ventilators, anesthesia machines and spirometers.<\/p>\n<p>Our biomedical testing devices PF-300, PF-301 or PF-302 distinguish themselves from other calibration tools by combining a simple, intuitive multilingual user interface with the highest precision. All measured values can be stored directly on the FlowAnalyser and later retrieved for documentation purposes with the push of a button. FlowLab software complements the FlowAnalyser Ventilator tester by offering a wide range of graphical analysis capabilities. Swiss devotion to detail at its best!<\/p>\n<table class=\"product-specs__table\">\n<tbody>\n<tr class=\"table__supertitle\">\n<td colspan=\"3\"><strong>\u6d41\u91cf\u3068\u5727\u529b\u306e\u6e2c\u5b9a<\/strong><\/td>\n<td><strong>PF-300<\/strong><\/td>\n<td><strong>PF-301<\/strong><\/td>\n<td><strong>PF-302<\/strong><\/td>\n<\/tr>\n<tr class=\"table__title\">\n<td colspan=\"6\"><b>\u30d5\u30ed\u30fc<\/b><\/td>\n<\/tr>\n<tr>\n<td>Flow in High-Flow-Channel<\/td>\n<td>\u30d5\u30ed\u30fc<sub>\u9ad8\u3044<\/sub><\/td>\n<td>\u00b1300 L\/\u5206<br \/>\n\u00b11.75 %* or \u00b10.1 L\/min**<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>Flow in Low-Flow-Channel<\/td>\n<td>\u30d5\u30ed\u30fc<sub>Low<\/sub><\/td>\n<td>\u00b120 L\/min***<br \/>\n\u00b11.75 %* or \u00b10.04 L\/min**<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>\u53cc\u65b9\u5411\u6027\u306e\u6e2c\u5b9a<\/td>\n<td>&nbsp;<\/td>\n<td>\u306f\u3044<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>\u6e29\u5ea6\u88dc\u511f<\/td>\n<td>&nbsp;<\/td>\n<td>\u81ea\u52d5<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>\u5727\u529b\u88dc\u511f<\/td>\n<td>&nbsp;<\/td>\n<td>\u81ea\u52d5<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>\u6e7f\u5ea6\u88dc\u511f\u4ed8\u304d<\/td>\n<td>&nbsp;<\/td>\n<td>\u81ea\u52d5<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>Oxygen compensated<\/td>\n<td><\/td>\n<td>\u81ea\u52d5<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr class=\"table__title\">\n<td colspan=\"6\"><b>\u5727\u529b<\/b><\/td>\n<\/tr>\n<tr>\n<td>\u9ad8\u3044<\/td>\n<td>P<sub>\u9ad8\u3044<\/sub><\/td>\n<td>0\uff5e10\u30d0\u30fc\u30eb<br \/>\n\u00b11 %* \u307e\u305f\u306f \u00b110 mbar**<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>\u30c7\u30a3\u30d5\u30a1\u30ec\u30f3\u30b7\u30e3\u30eb<\/td>\n<td>P<sub>\u62e1\u6563<\/sub><\/td>\n<td>\u00b1150 mbar<br \/>\n\u00b10.75 %* \u307e\u305f\u306f \u00b10.1 mbar**<\/td>\n<td>\u25cf<\/td>\n<td>&nbsp;<\/td>\n<td>&nbsp;<\/td>\n<\/tr>\n<tr>\n<td>Relative Pressure<\/td>\n<td>&nbsp;<\/td>\n<td>\u00b1150 mbar<br \/>\n\u00b10.75 %* \u307e\u305f\u306f \u00b10.1 mbar**<\/td>\n<td>&nbsp;<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>\u6d41\u8def<\/td>\n<td>P<sub>\u30c1\u30e3\u30f3\u30cd\u30eb<\/sub><\/td>\n<td>0-150 mbar<br \/>\n\u00b10.75 %* \u307e\u305f\u306f \u00b10.1 mbar**<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>\u5927\u6c17\u5727<\/td>\n<td>P<sub>\u30a2\u30c8\u30e2<\/sub><\/td>\n<td>0\u20131150 mbar (abs)<\/p>\n<p>\u00b11 %* or \u00b1 5 mbar**<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>Low<\/td>\n<td>P<sub>Low<\/sub><\/td>\n<td>0\u20135 mbar<\/p>\n<p>\u00b11 %* or \u00b1 0.01 mbar**<\/td>\n<td><\/td>\n<td><\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>Vacuum<\/td>\n<td>P<sub>Vac<\/sub><\/td>\n<td>\u00b1 1000 mbar<\/p>\n<p>\u00b10.5 %* or \u00b1 2 mbar**<\/td>\n<td><\/td>\n<td>\u25cf<\/td>\n<td><\/td>\n<\/tr>\n<tr class=\"table__title\">\n<td colspan=\"6\"><strong>\u5358\u4f4d<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u30d5\u30ed\u30fc<\/td>\n<td>&nbsp;<\/td>\n<td>L\/\u5206\u3001L\/s\u3001cfm\u3001mL\/\u5206\u3001mL\/s<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>\u5727\u529b<\/td>\n<td>&nbsp;<\/td>\n<td>bar\u3001mbar\u3001cmH<sub>2<\/sub>O\u3001inH<sub>2<\/sub>O\u3001Torr\u3001inHg\u3001hPa\u3001kPa\u3001mmHg\u3001PSI<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr class=\"table__title\">\n<td colspan=\"6\"><strong>Other measurement<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u9178\u7d20<br \/>\n(\u5727\u529b\u30b3\u30f3\u30d7\u2264 150 mbar)<\/td>\n<td>O<sub>2<\/sub><\/td>\n<td>0-100 %<br \/>\n\u00b11 % O<sub>2<\/sub>**<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>\u30ac\u30b9\u6e29\u5ea6<\/td>\n<td>\u6c17\u6e29\u3002<\/td>\n<td>0-50\u00b0C<br \/>\n\u00b11.75 %*\u307e\u305f\u306f\u00b10.5 \u2103***\u3002<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>Gas humidity<\/td>\n<td>\u6e7f\u5ea6<\/td>\n<td>0-100% RH\uff08\u975e\u51dd\u7e2e\u578b\uff09<br \/>\n\u00b13 % RH ** 10% RH \uff5e 80% RH<br \/>\n\u00b15 % RH ** 10% \u672a\u6e80\u304a\u3088\u3073 80% RH \u8d85\u306e\u5834\u5408<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>\u30ac\u30b9\u7a2e<\/td>\n<td>&nbsp;<\/td>\n<td>\u30a8\u30a2\u3001\u30a8\u30a2\/O<sub>2<\/sub>, O<sub>2<\/sub>, N<sub>2<\/sub>O, N<sub>2<\/sub>O\/O<sub>2<\/sub>, N<sub>2<\/sub>He\u3001He\/O<sub>2<\/sub>\u30ac\u30b9\u7a2e\u306e\u30ab\u30b9\u30bf\u30de\u30a4\u30ba<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr class=\"table__title\">\n<td colspan=\"6\">\u305d\u306e\u4ed6\u306e\u30ac\u30b9\u7a2e<\/td>\n<\/tr>\n<tr>\n<td>CO<sub>2<\/sub><\/td>\n<td>\u96c6\u4e2d\uff08\u30aa\u30d7\u30b7\u30e7\u30f3\u306eOR-703\u3092\u4f7f\u7528\uff09<\/td>\n<td>0\u201310 %, \u00b1(0.2 % ABS + 2 % REL)<\/p>\n<p>10\u201320 %, \u00b1(0.3 % ABS + 4 % REL)<\/td>\n<td>\u30aa\u30d7\u30b7\u30e7\u30f3<\/td>\n<td>\u30aa\u30d7\u30b7\u30e7\u30f3<\/td>\n<td>\u30aa\u30d7\u30b7\u30e7\u30f3<\/td>\n<\/tr>\n<tr>\n<td>N<sub>2<\/sub>O<\/td>\n<td>\u96c6\u4e2d\uff08\u30aa\u30d7\u30b7\u30e7\u30f3\u306eOR-703\u3092\u4f7f\u7528\uff09<\/td>\n<td>0\u2013100 %, \u00b1(2 % ABS + 2 % REL)<\/td>\n<td>\u30aa\u30d7\u30b7\u30e7\u30f3<\/td>\n<td>\u30aa\u30d7\u30b7\u30e7\u30f3<\/td>\n<td>\u30aa\u30d7\u30b7\u30e7\u30f3<\/td>\n<\/tr>\n<tr>\n<td>HAL\u3001ISO\u3001ENF<\/td>\n<td>\u96c6\u4e2d\uff08\u30aa\u30d7\u30b7\u30e7\u30f3\u306eOR-703\u3092\u4f7f\u7528\uff09<\/td>\n<td>0\u20138 %, \u00b1(0.15 % ABS + 5 % REL)<\/p>\n<p>8\u201312 %, \u00b1(0.2 % ABS + 10 % REL)<\/td>\n<td>\u30aa\u30d7\u30b7\u30e7\u30f3<\/td>\n<td>\u30aa\u30d7\u30b7\u30e7\u30f3<\/td>\n<td>\u30aa\u30d7\u30b7\u30e7\u30f3<\/td>\n<\/tr>\n<tr>\n<td>\u30bb\u30d6<\/td>\n<td>\u96c6\u4e2d\uff08\u30aa\u30d7\u30b7\u30e7\u30f3\u306eOR-703\u3092\u4f7f\u7528\uff09<\/td>\n<td>0\u201310 %, \u00b1(0.15 % ABS + 5 % REL)<\/p>\n<p>10\u201315 %, \u00b1(0.2 % ABS + 10 % REL)<\/td>\n<td>\u30aa\u30d7\u30b7\u30e7\u30f3<\/td>\n<td>\u30aa\u30d7\u30b7\u30e7\u30f3<\/td>\n<td>\u30aa\u30d7\u30b7\u30e7\u30f3<\/td>\n<\/tr>\n<tr>\n<td>DES<\/td>\n<td>\u96c6\u4e2d\uff08\u30aa\u30d7\u30b7\u30e7\u30f3\u306eOR-703\u3092\u4f7f\u7528\uff09<\/td>\n<td>0\u201322 %, \u00b1(0.15 % ABS + 5 % REL)<\/p>\n<p>22\u201325 %, \u00b1(0.2 % ABS + 10 % REL)<\/td>\n<td>\u30aa\u30d7\u30b7\u30e7\u30f3<\/td>\n<td>\u30aa\u30d7\u30b7\u30e7\u30f3<\/td>\n<td>\u30aa\u30d7\u30b7\u30e7\u30f3<\/td>\n<\/tr>\n<tr>\n<td>\u30ac\u30b9\u898f\u683c<\/td>\n<td>&nbsp;<\/td>\n<td>atp\u3001atpd\u3001atps\u3001ap21\u3001stp\u3001stph\u3001btps\u3001btps-a\u3001btpd\u3001btpd-a\u30010\/1013\u300120\/981\u300115\/1013\u300125\/991\u300120\/1013\u3001ntpd\u3001ntps<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr class=\"table__title\">\n<td colspan=\"6\"><strong>Ventilation Parameter<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u547c\u5438\u6570<\/td>\n<td>\u30ec\u30fc\u30c8<\/td>\n<td>1-1000 bpm<br \/>\n\u00b11 bpm* \u307e\u305f\u306f \u00b12.5 %**.<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>\u6642\u9593<\/td>\n<td>T<sub>i<\/sub>, T<sub>e<\/sub><\/td>\n<td>0.05\u201360s<br \/>\n\u00b10.02 s<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>\u6bd4\u7387<\/td>\n<td>I:E<\/td>\n<td>1:300-300:1<br \/>\n\u00b12.5 %<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>&nbsp;<\/td>\n<td>T<sub>i<\/sub>\/T<sub>\u30b5\u30a4\u30af<\/sub><\/td>\n<td>0-100 %<br \/>\n\u00b15 %<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>Volume<\/td>\n<td>V(Low), V(High)<\/td>\n<td>\u00b11.75 %* or \u00b10.10 mL (&gt;2.4 L\/min)**<br \/>\n\u00b11.75 %* or \u00b10.20 mL (&gt;6.0 L\/min)**<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>\u6f6e\u6c50\u91cf<\/td>\n<td>V<sub>\u30c6\u30a3<\/sub>, V<sub>\u30c6\u30a3\u30fc<\/sub><\/td>\n<td>\u00b1 10 L<\/p>\n<p>\u00b11.75 %* or \u00b10.10 mL (&gt;2.4 L\/min)**<br \/>\n\u00b11.75 %* or \u00b10.20 mL (&gt;6.0 L\/min)**<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>\u5206\u91cf<\/td>\n<td>V<sub>i<\/sub>, V<sub>e<\/sub><\/td>\n<td>0-300 L\/\u5206<br \/>\n\u00b12.5 %<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>\u30d4\u30fc\u30af\u30d5\u30ed\u30fc<\/td>\n<td>\u9801<sub>\u30a4\u30f3\u30b9\u30d1\u30a4\u30a2<\/sub>PF<sub>\u30a8\u30af\u30b9\u30dd<\/sub><\/td>\n<td>\u00b1 300 L\/\u5206<br \/>\n\u00b11.75 %* or \u00b10.1 L\/min**<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>\u5727\u529b<\/td>\n<td>P<sub>\u30d4\u30fc\u30af<\/sub>, P<sub>\u5e73\u5747<\/sub>PEEP\u3001P<sub>\u30d7\u30e9\u30c8\u30fc<\/sub><\/td>\n<td>0-150 mbar<br \/>\n\u00b10.75 %* \u307e\u305f\u306f \u00b10.1 mbar**<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>\u30b3\u30f3\u30d7\u30e9\u30a4\u30a2\u30f3\u30b9<\/td>\n<td>C<sub>\u30b9\u30bf\u30c3\u30c8<\/sub><\/td>\n<td>0-1000 mL\/mbar<br \/>\n\u00b13 %* \u307e\u305f\u306f \u00b11 mL\/mbar**<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr class=\"table__title\">\n<td colspan=\"6\"><strong>\u4e00\u822c\u60c5\u5831<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u30c7\u30a3\u30b9\u30d7\u30ec\u30a4<\/td>\n<td>&nbsp;<\/td>\n<td>Intuitive user interface with numerical measuring values, statistics, volume trigger configuration, gas type selection and calibration menus.<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>\u30a4\u30f3\u30bf\u30fc\u30d5\u30a7\u30a4\u30b9<\/td>\n<td>&nbsp;<\/td>\n<td>USB for Windows Software FlowLab, RS-232 for individual communication, TTL for external trigger and TSI4000 Protocol.<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>\u30c7\u30fc\u30bf\u4fdd\u7ba1<\/td>\n<td>&nbsp;<\/td>\n<td>\u5185\u90e8<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>\u30d1\u30ef\u30fc<\/td>\n<td>&nbsp;<\/td>\n<td>100-240 VAC\u300150\/60 Hz<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>\u6d88\u8cbb\u96fb\u529b<\/td>\n<td><\/td>\n<td>25 VA<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>\u5bf8\u6cd5\uff08\u5e45\u00d7\u5965\u884c\u00d7\u9ad8\u3055\uff09<\/td>\n<td>&nbsp;<\/td>\n<td>22 \u00d7 25 \u00d7 12 cm<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>\u91cd\u91cf<\/td>\n<td>&nbsp;<\/td>\n<td>3.7 kg<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>\u30d0\u30c3\u30c6\u30ea\u30fc<\/td>\n<td>&nbsp;<\/td>\n<td>3 hours (with OR-703 2 hours)<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>Emlators<\/td>\n<td><\/td>\n<td>RT-200, TSI4000<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>\u627f\u8a8d<\/td>\n<td>&nbsp;<\/td>\n<td>CE, CSA (North America), IEC 61010-1:2010, IEC 61326-2:2012<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><small>\u3088\u308a\u5927\u304d\u306a\u8a31\u5bb9\u7bc4\u56f2\u304c\u6709\u52b9\u3067\u3042\u308b\uff1a<br \/>\n* \u6e2c\u5b9a\u5024\u306b\u95a2\u3059\u308b\u516c\u5dee\u3001<br \/>\n** \u7d76\u5bfe\u7684\u306a\u8a31\u5bb9\u7bc4\u56f2\u3001<br \/>\n*** \u5358\u4f4dL\/min\u306f\u3001\u5468\u56f2\u6e29\u5ea60\u2103\u30011013.25 mbar\uff08DIN 1343\uff09\u306b\u57fa\u3065\u304f\u3002<\/small><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/article>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>\u30d0\u30a4\u30e4\u30fc\u901a\u77e5<br \/>\n1.\u88fd\u54c1\u306b\u3064\u3044\u3066<br \/>\n\u5e02\u5834\u306e\u5909\u52d5\u3001\u70ba\u66ff\u30ec\u30fc\u30c8\u306e\u5909\u5316\u3001\u305d\u306e\u4ed6\u306e\u8981\u56e0\u306e\u305f\u3081\u3001\u88fd\u54c1\u4fa1\u683c\u3068\u88fd\u54c1\u5c5e\u6027\u306f\u53c2\u8003\u306e\u307f\u3067\u3042\u308a\u3001\u5177\u4f53\u7684\u306a\u88fd\u54c1\u8981\u4ef6\u306f\u9867\u5ba2\u306e\u8981\u4ef6\u306b\u5f93\u3046\u3082\u306e\u3068\u3057\u3001\u4fa1\u683c\u306f\u9023\u7d61\u3055\u308c\u305f\u898b\u7a4d\u66f8\u306b\u57fa\u3065\u304f\u3082\u306e\u3068\u3057\u307e\u3059\u3002\u672c\u30a6\u30a7\u30d6\u30b5\u30a4\u30c8\u4e0a\u306e\u88fd\u54c1\u4fa1\u683c\u306f\u3059\u3079\u3066\u53d6\u5f15\u4fa1\u683c\u3068\u306f\u307f\u306a\u3055\u308c\u305a\u3001\u53c2\u8003\u4fa1\u683c\u3068\u306a\u308a\u307e\u3059\uff01<br \/>\n2.\u5546\u6a19\u6a29\u306b\u3064\u3044\u3066<br \/>\n\u5f53\u30a6\u30a7\u30d6\u30b5\u30a4\u30c8\u306b\u63b2\u8f09\u3055\u308c\u3066\u3044\u308b\u4f1a\u793e\u540d\u3001\u5546\u6a19\u3001\u30ed\u30b4\u3001\u5546\u54c1\u753b\u50cf\u3001\u5546\u54c1\u8aac\u660e\u3001\u5546\u54c1\u30d6\u30e9\u30f3\u30c9\u540d\u3001\u5546\u6a19\u306e\u8457\u4f5c\u6a29\u306f\u3001\u5404\u30d6\u30e9\u30f3\u30c9\u306b\u5e30\u5c5e\u3057\u307e\u3059\u3002<br \/>\n\u4e0d\u5fc5\u8981\u306a\u7d1b\u4e89\u3092\u907f\u3051\u308b\u305f\u3081\u3001\u30d0\u30a4\u30e4\u30fc\u306e\u6307\u793a\u3092\u3088\u304f\u304a\u8aad\u307f\u304f\u3060\u3055\u3044\u3002<\/p>","protected":false},"excerpt":{"rendered":"<p>\u30d6\u30e9\u30f3\u30c9\uff1aIMT\u30a2\u30ca\u30ea\u30c6\u30a3\u30af\u30b9<br \/>\nModel:PF-300<br \/>\n\u88fd\u54c1\u306b\u3064\u3044\u3066\u304a\u77e5\u308a\u306b\u306a\u308a\u305f\u3044\u65b9\u306f\u3001\u5f53\u793e\u307e\u3067\u3054\u9023\u7d61\u304f\u3060\u3055\u3044\u3002<br \/>\n\u304a\u554f\u3044\u5408\u308f\u305b\u306e\u969b\u306f\u3001\u30d6\u30e9\u30f3\u30c9\u3001\u30e2\u30c7\u30eb\u3001\u6570\u91cf\u3092\u304a\u77e5\u3089\u305b\u304f\u3060\u3055\u3044\u3002<\/p>","protected":false},"featured_media":8964,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[15],"product_tag":[],"class_list":["post-8963","product","type-product","status-publish","has-post-thumbnail","hentry","product_cat-uncategorized"],"_links":{"self":[{"href":"https:\/\/www.wbusi.com\/ja\/wp-json\/wp\/v2\/product\/8963","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wbusi.com\/ja\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.wbusi.com\/ja\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wbusi.com\/ja\/wp-json\/wp\/v2\/comments?post=8963"}],"version-history":[{"count":1,"href":"https:\/\/www.wbusi.com\/ja\/wp-json\/wp\/v2\/product\/8963\/revisions"}],"predecessor-version":[{"id":8965,"href":"https:\/\/www.wbusi.com\/ja\/wp-json\/wp\/v2\/product\/8963\/revisions\/8965"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wbusi.com\/ja\/wp-json\/wp\/v2\/media\/8964"}],"wp:attachment":[{"href":"https:\/\/www.wbusi.com\/ja\/wp-json\/wp\/v2\/media?parent=8963"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.wbusi.com\/ja\/wp-json\/wp\/v2\/product_cat?post=8963"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.wbusi.com\/ja\/wp-json\/wp\/v2\/product_tag?post=8963"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}